EN7016SK EchoStream
Survey Kit
Installation and Operation Manual - 04493D
1 Quick Start
By following this procedure you can quickly configure the supplied
equipment to perform a site survey. Review the main body of this
manual for additional options, features and a more detailed startup
process.
Note: If performing site surveys in Australia or New Zealand, the
additional setup steps in the main body of this manual must be
performed.
1. Slide off the battery cover on the back of the EN4016SK survey
receiver.
2. Load four AA batteries into the survey kit receiver.
3. Press the Power button to turn on the survey kit receiver.
Figure 1 EN4016SK Survey Receiver
4. Press the Enter button to advance to M
AIN MENU.
5. Select R
EGISTER POINT on the MAIN MENU.
6. Select P
OINT 1 on the REGISTER POINT menu.
7. Press the EN1223SK Reset button.
Figure 2 EN1223SK Survey Transmitter
8. Select P
ENDANT. The survey transmitter should now be
registered.
9. Press the EN1223SK On/Off button. The transmit LED should
begin to flash.
10.Use the small flat-blade screwdriver to press the housing
release tab on either end of the ES1210SK and separate the
housing.
11.Select P
OINT 2 on the REGISTER POINT menu.
12.Press the ES1210SK Reset button. The transmitter should now
be registered.
Figure 3 ES1210SK Survey Transmitter
13.Press the ES1210SK On/Off button. The transmit LED should
begin to flash.
14.Place the survey transmitters where you plan to mount your
network coordinator or receiver.
15.Walk the receiver to the first point you plan to use a transmitter
or a two-way end device.
Note: Reversing the position of the end device and the high-power
repeater will make the survey easier to perform. This equipment
reversal will not affect the accuracy of the results.
16.Press Exit to return to the M
AIN MENU.
17.Select P
OINT STATUS on the MAIN MENU.
18.Select P
OINT 1 or POINT 2 to view signal information.
Figure 4 The Point Status Summary Screen
Power
Button
Enter
Button
Exit
Button
Reset
Button
On/Off
Button
Transmit
LED
On/Off
Button
Reset
Button
Frequency
Band
Selection
Pins
Transmit
LED
Signal
Quality
Transmission
Symbols
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - Survey Kit

© Inovonics, 2011 - www.inovonics.comEN7016SK EchoStream™ Survey KitInstallation and Operation Manual - 04493D1 Quick StartBy following this procedure

Page 2 - Frequency Band

© Inovonics, 2011 - www.inovonics.com 22 EN7016SK OverviewThe EchoStream survey kit is a portable, easy-to-use system for conducting EchoStream site

Page 3

© Inovonics, 2011 - www.inovonics.com 3 Figure 7 EN1223SK Frequency Band Selection Options4. Close the housing and replace the three housing screws.

Page 4 - 5 Register End-Devices

© Inovonics, 2011 - www.inovonics.com 4 Figure 11 Survey Receiver Keypad.The MAIN MENU displays: Figure 12 The Main Menu, Point Status HighlightedT

Page 5

© Inovonics, 2011 - www.inovonics.com 51. Highlight REGISTER POINT on the main menu. Figure 17 The Main Menu, Register Point Highlighted2. Press En

Page 6 - Transmitters

© Inovonics, 2011 - www.inovonics.com 6From the main menu, highlight POINT STATUS, and press Enter to select. The REGISTER POINT menu displays. Figur

Page 7 - 10 Warranty/Disclaimer

9 SpecificationsOperating frequency 915-928 MHz (Australia), 921-928 MHz (New Zealand) 902-928 MHz (USA)Operating environment 0°- 60°C (32°- 140°F), 9

Comments to this Manuals

No comments