EE4232M EchoStream® Receiver
Installation and Operation Manual - 05396I
1 Overview
Inovonics EchoStream technology is designed to minimize dead spots in transmission
areas using diversity reception and advanced signal processing. The EE4232M
receiver allows you to add up to 32 transmitters and 12 outputs to any application.
The EE4232M is compliant with:
EN50131-1
Security Grade 2
Environmental Class II
1.1 Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics Wireless technical
services:
E-mail: support@inovonics.com
Phone: (800) 782-2709; (303) 939-9336
1.2 EE4232M Front Panel
Figure 1 Receiver front panel
Up Button Scrolls the display up.
Down button: Scrolls the display down.
Back button: Returns display to the previous menu, or, when entering information in
the display, returns to the last character entered.
Enter button: Selects the currently displayed menu item. If in normal operating mode,
sets the unit to menu mode.
LCD Display: Shows status, event log and programming information.
Note: The EE4232M LCD will only display information when an authorized password
has been entered.
1.3 EE4232M Internal Components
Figure 2 EE4232M internal components
1.4 EE4232M LEDs
Note: The EE4232M operation LEDs are only visible when the cover is removed.
Output LED: Lights when any output is active.
Fault LED: Lights when any transmitter is sending a fault condition.
Power LED: Lit when receiving power.
Decode LED: Flashes when any recognizable transmission is received. This LED is
only visible with the cover removed.
2 Installation and Startup
2.1 Connect Power Cabling
Before beginning startup, you will need to connect power to the receiver. To connect
power to the receiver:
Caution: Graded application must use the cabling knockout on the back of the
housing.
1. Connect power cabling to the Vs and GND connections.
Power source should be 11-14 VDC. Power supply must be unswitched,
uninterrupted, and regulated.
2.2 Enable EchoStream Select
To meet ETSI requirements, Inovonics has developed a new line of EE 868MHz-only
products. These new 868MHz-only products are compatible with older systems that
include EchoStream Select products. If you are using any ES products in your current
system, you will need to enable EchoStream Select compatibility on this new 868MHz-
only product.
To enable/disable EchoStream Select compatibility:
1. To enable compatibility with ES products, place a selection jumper on the ES
selection pins.
Note: Selection jumpers are included in the EE4232M hardware packet.
2. If no ES products are used in your system, remove the selection jumper from the
ES selection pins.
3. Reset the receiver or cycle power.
2.3 Enter Password
There are three levels of EE4232 user. Only the level 2 authorized user and level 3
authorized installer are able to access the I
NSTALL & SERVICE menu.
Level 2 authorized user access: A level 2 authorized user has the ability to view
system status indicators and enter system test mode in the I
NSTALL & SERVICE menu.
A level 2 user does not have the ability to change receiver parameters or perform
receiver functions (signal strength, test, register points, etc.). For more information on
system test mode, see “System Test Mode” on page 3.
Note: The default level 2 authorized user password is 3446.
Level 3 authorized installer access: A level 3 authorized installer has the ability to
access all I
NSTALL & SERVICE menus. A level 3 authorized installer can also view
receiver system status indicators as well as change receiver system parameters and
perform all receiver functions.
Note: The default level 3 authorized installer password is 1234.
During normal operation there is no visual indication of system status or activity on the
front display of the EE4232M receiver. Unless the level 2 authorized user or the level 3
authorized installer enters a valid password, the LCD will remain completely blank.
To enter either the level 2 authorized user or the level 3 authorized installer password:
1. Press any button; P
ASSWORD displays.
2. Use the Up and Down buttons to scroll through the first numeral; press Enter to
select.
3. Repeat step 2 for each numeral in the password.
4. When all numerals in the password have been entered, press Enter to submit the
password.
2.4 Select Display Language
On initial startup you will need to select the display language. Once selected, the
language will be maintained unless changed using the C
HANGE LANGUAGE option in
the I
NSTALL & SERVICE menu. To select the display language, see “Select Language”
on page 3.
2.5 Navigate to the Install & Service Menu
There are three main menus: POINT STATUS, INSTALL & SERVICE and EVENT LOG. The
INSTALL & SERVICE menu is used to program outputs, select language, change
password, view the signal strength, delete points, register transmitters, and setup
points for any of the programmed points.
Note: If changing programming for a point that already has a transmitter registered to
it, there is no need to re-register the transmitter. Changes to point programming are
automatically assigned to the transmitter registered to that point.
To access the I
NSTALL & SERVICE menu:
1. From the R
EADY prompt, press the Enter button to access the receiver’s three
main menus.
2. Use the Up and Down buttons to navigate to the the I
NSTALL & SERVICE menu;
press the Enter button.
2.6 Program Output
1. From the INSTALL & SERVICE menu, use the Up and Down buttons to navigate to
the P
ROGRAM OUTPUT prompt; press the Enter button.
2. P
ROGRAM OUT 01 displays. Use the Up and Down buttons to scroll through points;
press Enter to select the point you want to program.
3. The O
UT N/O, N/C prompt displays. Use the Up and Down buttons to choose N/O
or N/C; press Enter to select.
4. The P
GM DONE prompt displays; press the Enter button and use the Up and
Down buttons to select the next output to program.
5. When you’ve completed programming all the points you wish to program, use the
Back button to return to the I
NSTALL & SERVICE menu.
A Up button B Down button C Back button D Enter button E LCD display
A Housing release tabs B Power connections C Operation LEDs
D Output terminals E Tamper output F Clear to set output
G Jam output H Reset input I EchoStream Select pins
A
B
C
D
E
A
B
C
D
G
H
F
E
A
A
I
Page view 0
1 2 3 4

Summary of Contents

Page 1 - EE4232M EchoStream® Receiver

© Inovonics, 2011 - www.inovonics.comEE4232M EchoStream® ReceiverInstallation and Operation Manual - 05396I1 OverviewInovonics EchoStream technology i

Page 2 - 2.10 Monitor Signal Strength

© Inovonics, 2011 - www.inovonics.com 22.7 Setup Point1. From the INSTALL & SERVICE menu, press Enter at the SETUP POINT prompt.2. Use the Up/Dow

Page 3 - 4 Operation

© Inovonics, 2011 - www.inovonics.com 32.11 CTS TypeThe EE4232M provides a signal to the control panel which can be used to ensure all security devic

Page 4 - 7 Specifications

© Inovonics, 2011 - www.inovonics.com 4 Figure 3 EE4232M Terminals6 Mount the ReceiverCaution: Mount the receiver in a location removed from metal.