© Inovonics, 2011 - www.inovonics.com 5
14 ADT Focus 200 Plus / Focus Cadet Control Panel Wiring and Programming Information
14.1 Typical EN4216MR Receiver Connection to ADT Focus 200 Plus / Focus Cadet Control Panel
EN4216MR Function EN4216MR
Terminal
Panel Terminal Keypad Text
Power in (12V DC) Vs (19) + Aux Power n/a
Ground GND (20) - Aux Power n/a
Alarm 1 NC (1) (25) Point 1 (user text)
(Follower) Com 1 (26) Common
NO (1)
Alarm 2 NC (2) (27) Point 2 (user text)
(Follower) Com 2 (28) Common
NO (2)
Repeater AC Loss NC (3) (29) Point 3 RF Repeater AC
(Follower) Com 3 (30) Common
NO (3)
RF Pt Low Battery NC (4) (32) Point 4 RF Pt Low Batt
(Latching) Com 4 (31) Common
NO (4)
RF Pt Tamper NC (5) RF Pt Trouble
(Latching) Com 5 (34) Common
NO (5)* (33) Point 5
RF Pt Inactive NC (6) (35) Point 6 RF Pt Inactive
(Follower) Com 6 (34) Common
NO (6)
Power Loss POWER LOSS (36) Point 7 RF Recvr Power
(Follower) (37) n/a
Receiver Tamper TAMP * n/a n/a
RF Jam JAM (38) Point 8 RF System Jammed
(Follower) (37) n/a
* Point 5 is normally open to allow RF Pt Tamper and Receiver Tamper on one loop.
The end-of-line resistor must not be in series with the wire from terminal NO (5) to terminal 33. Add the following 2 connections to
terminate the combined loop:
1. Connect a wire from TAMP terminal to NO (5) terminal.
2. Connect a 2K-ohm resistor from TAMP terminal to COM 5 terminal.